Warning about frequencies with COSMO model
Numerical frequencies calculated with COSMO should be checked for stability
with respect to the disrad, the numerical differentiation step size. The problem
is that the COSMO surface changes slightly when a nucleus is moved from its
equilibrium position. The change is usually smal but in some cases it may result is
creation or annihilation of surface points, which will lead to discontinuities in the
potential energy surface and may result in inaccurate frequencies.
Thus, when calculating vibrational frequencies numerically with COSMO, one should try
decreasing the disrad value until no changes in frequencies are observed.
However, the value should not be too small because then the total numerical noise may become
too large compared to the generated forces. A general recommendation would be to
try to decrease disrad by a factor of 2 at a time. Of course, this procedure may be
very expensive for a large molecule. If this the case, one should use the SCANFREQ
keyword and recalculate only a small number of frequencies. It should be noted that
generally frequencies that have a small force constant are more sensitive to the
numerical noise.
|