Convergence difficulties with spin-unrestricted calculations
If spin-unrestricted calculations fail to
converge, you may try to run first a restricted calculation. Then perform the
unrestricted while using the TAPE21 from the earlier run as a restart file.
Now, in the restart run you have two alternatives that may stand a better
chance to give you the desired result than your original failing calculation:
(1) Apply
the MODIFYSTARTPOTENTIAL key to steer the (at the least the initial)
spin-density on a per-atom (fragment) basis towards what you expect should be
the final self-consistent situation. It may be necessary to apply stronger
damping, or do other SCF convergence tricks like level shifting, in order to
preserve your initial construction long enough for the system to get near the
minimum it should converge to. It is recommended to supply occupation numbers
(in case the system has symmetry) in input.
(2) If
all SCF tricks fail (but you did get the restricted converged result), you may simply run a one-cycle
unrestricted run, specifying the occupation numbers you consider appropriate
and so obtain the unrestricted occupation state for the
restricted-self-consistent MOs. The difference with the 'true' converged unrestricted MOs is often quite small. See the Examples
document for the discussion of a similar case (H2).
|