Energy Functional
The energy functional consists of coulomb, kinetic and
exchange-correlation (xc) terms.
The starting point for the xc functional
is usually the result for the homogeneous electron gas, after which so
called
nonlocal or generalized gradient corrections (GGA: Generalized Gradient
Approximation) are added.
See the keys Spin
and XC.
The program calculates by default the self-consistent field
solution from the potential in the spin-restricted local density
approximation
(LDA) to the exchange-correlation (XC) potential.
The post-SCF generalized gradient (GGA) corrections for the exchange
and the correlation energies (each
for a few different functionals) are calculated and printed on output.
The
program can be instructed to use the GGA corrections in the potential
during
the SCF as well. This will in general have little effect on the
formation
energy, but it may affect the Density of States (DOS).
Relativistic effects are treated with the accurate and efficient ZORA
approach, see the Relativistic keyword.
|