Dear Dr Swart
I have checked the dipole moment, polarizability across the programs and the results are summarized below.
The optimized standard orientation Phenylalanine is used in both packages. I then take these results and apply a Euler transformation in order to use a more convinient axes system (Z and X axes along the benzene ring).
Dipole Moment / Debye
Gaussian 98 (MP2/Sadlej) : x=-1.98,y=4.37,z=-0.02
Gaussian 98 (HF/Sadlej) : x=-2.13,y=4.89,z=-0.24
ADF (LB94/Vdiff) : x=-2.10,y=4.75,z=-0.10
Polarizability / au
Gaussian 98 (MP2/Sadlej) : axx=134.42,ayy=125.60,azz=99.71
Gaussian 98 (HF/Sadlej) : axx=126.79,ayy=119.40,azz=93.84
ADF (LB94/Vdiff) : axx=137.06,ayy=126.61,azz=97.13
Hyperpolarizability / au
Gaussian 98 (MP2/Sadlej) : bxxx=-59.03,byyy=47.78,bzzz=-10.56
Gaussian 98 (HF/Sadlej) : bxxx=-71.82,byyy=43.20,bzz=-16.30
ADF (LB94/Vdiff) : bxxx=57.45,byyy=-75.22,bzzz=-15.18
Also the Gamess-US package (HF/Sadej) gives the same results with Gaussian 98 (HF/Sadlej)
It appears dipole moment and polarizability tensors agree in sign across the two packages but not the bxxx and byyy tensors. Maybe the basis set is responsible for this. Have repeated calculations with 6-311G(d,p) in Gaussian and got agreement in sign between bxxx but not byyy.
Many Thanks for your help
Best Regards
Lefteris
----- Original Message -----
From: Marcel Swart
To: Lefteris Danos
Cc: adf-list_at_scm.com
Sent: Friday, August 06, 2004 9:06 PM
Subject: Re: ADF-LIST: ADF-List: Sign of hyperpolarizabilities
Are you sure about the axes ??
For instance, for polarizabilities the first value given on output refers usually to YY, not XX;
I might think the same might be true for the beta.
[note: the output should tell you whether it gives xxx or yyy, or rather zzz or xxx]
Note also that you should check the atomic coordinates given in the output, because
it might also be that the coordinate system has changed; ADF usually rotates the molecule
based on the symmetry it finds.
On Friday, Aug 6, 2004, at 18:27 Europe/Amsterdam, Lefteris Danos wrote:
Dear ADF-users
I am comparing static hyperpolarisability values bewtween ADF (LB94/Vdiff) and Gaussian 98(MP2/Sadlej) for Phenylalanine and the calculated hyperpolarisability tensor components have opposite signs.
example:
bzzz (MP2/Sadlej-Gaussian98)= -32.53 au
bzzz (LB94/Vdiff-ADF)= 39.27 au
bzzz (HF/Sadlej-Gaussian98)= -48.26 au
I have used the same molecular orientation for both programs and all the hyperpolarisability tensor components come out with opposite signs to each other. Is there a reason for this possibly relating to the orientation of the applied electric fileds.
Thank you
Best Regards
Lefteris
######################################
Lefteris Danos
Research Fellow
Materials Research Group
School of Engineering Sciences
Highfield
University of Southampton
SO17 1BJ
UK
Tel: +44 (0) 238059 5101
Fax: +44 (0) 238059 3016
Email: lefteris_at_soton.ac.uk
######################################
末末末末末末末末末末末末末末末末末末末末末末
dr. Marcel Swart
Theoretische Chemie
Vrije Universiteit Amsterdam
Faculteit der Exacte Wetenschappen
De Boelelaan 1083
1081 HV Amsterdam
The Netherlands
Fax +31-20-4447629
E-mail m.swart_at_few.vu.nl
Web http://www.few.vu.nl/~swart
末末末末末末末末末末末末末末末末末末末末末末
Received on 2004-08-09 11:22:50
This archive was generated by hypermail 2.2.0 : 2006-11-02 07:00:02 CET