system Atoms Na 9.2386667530 4.0520826163 -5.4913920457 ForceField.Charge=1.0 ForceField.Type=IP Na 8.0262470001 8.8464077611 -4.1844520628 ForceField.Charge=1.0 ForceField.Type=IP Na 5.3352973618 7.7755583077 -1.5302033451 ForceField.Charge=1.0 ForceField.Type=IP Na -2.9856212661 1.2967879496 -6.1459178039 ForceField.Charge=1.0 ForceField.Type=IP Na 1.8901115767 5.2307237657 9.2295988897 ForceField.Charge=1.0 ForceField.Type=IP Cl -1.5159863130 -7.7840364295 -0.7626343500 ForceField.Charge=-1.0 ForceField.Type=IM Cl 6.5567005295 8.8615643447 0.7026374852 ForceField.Charge=-1.0 ForceField.Type=IM Cl 7.7380140536 -7.3179016774 -4.0185399165 ForceField.Charge=-1.0 ForceField.Type=IM Cl -3.1660925403 -9.1330211476 -8.8693221009 ForceField.Charge=-1.0 ForceField.Type=IM Cl -9.3285520221 -8.0426329074 6.9706738134 ForceField.Charge=-1.0 ForceField.Type=IM O -8.4063642812 -3.2988087074 0.9604414729 ForceField.Charge=-0.834 ForceField.Type=OW H -8.5406415028 -4.2187773241 0.6411519016 ForceField.Charge=0.417 ForceField.Type=HW H -9.2011573373 -3.1882204884 1.4800314357 ForceField.Charge=0.417 ForceField.Type=HW O 2.2459252602 9.4202167400 6.2308542882 ForceField.Charge=-0.834 ForceField.Type=OW H 1.8363874386 8.8516699216 5.5778690130 ForceField.Charge=0.417 ForceField.Type=HW H 2.9580942481 9.8462314769 5.7694576171 ForceField.Charge=0.417 ForceField.Type=HW O 9.0664244194 9.1848371701 4.6875396228 ForceField.Charge=-0.834 ForceField.Type=OW H 9.5691167739 9.4991634563 3.9366318508 ForceField.Charge=0.417 ForceField.Type=HW H 9.4016544560 9.7994704840 5.3838734720 ForceField.Charge=0.417 ForceField.Type=HW O 4.1949380763 -8.4401036963 1.9851039670 ForceField.Charge=-0.834 ForceField.Type=OW H 4.3939646791 -7.5191184323 1.7237324011 ForceField.Charge=0.417 ForceField.Type=HW H 4.8597941643 -8.9740080936 1.4556332622 ForceField.Charge=0.417 ForceField.Type=HW O -0.3001696164 8.1702630238 -8.4395920992 ForceField.Charge=-0.834 ForceField.Type=OW H -1.1659952335 8.6684310269 -8.3589402494 ForceField.Charge=0.417 ForceField.Type=HW H -0.5636049219 7.2647280597 -8.3559340300 ForceField.Charge=0.417 ForceField.Type=HW O 1.2927498151 7.3871003332 8.2731685435 ForceField.Charge=-0.834 ForceField.Type=OW H 1.5376733437 8.0676656246 7.5837117769 ForceField.Charge=0.417 ForceField.Type=HW H 0.6032034560 7.8269473911 8.8340628119 ForceField.Charge=0.417 ForceField.Type=HW O -0.4653949722 4.6538294075 1.3755859726 ForceField.Charge=-0.834 ForceField.Type=OW H 0.4453637604 4.3747447101 1.4705398578 ForceField.Charge=0.417 ForceField.Type=HW H -0.3140903026 5.6386812209 1.1476514157 ForceField.Charge=0.417 ForceField.Type=HW O 5.7328060790 3.7039111437 -7.6842039610 ForceField.Charge=-0.834 ForceField.Type=OW H 5.2307792706 3.3401023517 -8.4984244638 ForceField.Charge=0.417 ForceField.Type=HW H 5.3845600564 3.1375595992 -6.9806764577 ForceField.Charge=0.417 ForceField.Type=HW O -7.1219395112 5.7352653831 3.2074915009 ForceField.Charge=-0.834 ForceField.Type=OW H -6.6987532935 5.5212608645 2.3067457832 ForceField.Charge=0.417 ForceField.Type=HW H -6.6564844331 6.5839489179 3.4682605855 ForceField.Charge=0.417 ForceField.Type=HW O -8.6941981097 8.9086064881 -4.1732892484 ForceField.Charge=-0.834 ForceField.Type=OW H -8.0320466913 9.5431149220 -4.5001688899 ForceField.Charge=0.417 ForceField.Type=HW H -8.3579695730 8.7801968215 -3.2848408091 ForceField.Charge=0.417 ForceField.Type=HW O -8.7396011141 1.6915068118 -5.7665859778 ForceField.Charge=-0.834 ForceField.Type=OW H -7.9272500715 1.7134669161 -5.3616930911 ForceField.Charge=0.417 ForceField.Type=HW H -8.5531109356 1.0598383030 -6.4984115654 ForceField.Charge=0.417 ForceField.Type=HW O -1.5044960474 2.9493140133 4.3173327443 ForceField.Charge=-0.834 ForceField.Type=OW H -1.1783880424 3.3455873341 3.4748960961 ForceField.Charge=0.417 ForceField.Type=HW H -2.0539810476 3.5921180055 4.6727424151 ForceField.Charge=0.417 ForceField.Type=HW O -2.7934639176 3.1849663555 1.5839773841 ForceField.Charge=-0.834 ForceField.Type=OW H -2.7559157218 2.7483217611 0.6579254406 ForceField.Charge=0.417 ForceField.Type=HW H -1.9826955919 3.7568342050 1.5364126802 ForceField.Charge=0.417 ForceField.Type=HW O -2.8189302591 4.4777228612 9.2577694583 ForceField.Charge=-0.834 ForceField.Type=OW H -3.3847662272 3.7695759156 9.5389411943 ForceField.Charge=0.417 ForceField.Type=HW H -2.7729689727 4.3480308392 8.2868542414 ForceField.Charge=0.417 ForceField.Type=HW O 1.9632225779 3.4162195861 0.8910995073 ForceField.Charge=-0.834 ForceField.Type=OW H 2.6310887716 3.7946515320 1.5397513744 ForceField.Charge=0.417 ForceField.Type=HW H 2.6122474955 3.1646596580 0.2140718575 ForceField.Charge=0.417 ForceField.Type=HW O -1.5183473157 5.8190816470 -1.2583552514 ForceField.Charge=-0.834 ForceField.Type=OW H -1.9945598537 5.9954228407 -0.4029431260 ForceField.Charge=0.417 ForceField.Type=HW H -1.3718888126 6.7632362145 -1.5823774914 ForceField.Charge=0.417 ForceField.Type=HW O 9.4798883501 3.4357608051 -7.7832202652 ForceField.Charge=-0.834 ForceField.Type=OW H 9.1180613897 2.6412320006 -8.1682704765 ForceField.Charge=0.417 ForceField.Type=HW H 9.1375087205 4.1572082429 -8.3399193627 ForceField.Charge=0.417 ForceField.Type=HW O -4.0756564655 -5.9097092402 -1.8642313125 ForceField.Charge=-0.834 ForceField.Type=OW H -3.3467770621 -6.4487280972 -1.5731238524 ForceField.Charge=0.417 ForceField.Type=HW H -4.1287652636 -5.2405830317 -1.1707372579 ForceField.Charge=0.417 ForceField.Type=HW O -6.2472700747 5.1177284879 0.7836879120 ForceField.Charge=-0.834 ForceField.Type=OW H -5.6468588301 4.4334765087 0.4244842085 ForceField.Charge=0.417 ForceField.Type=HW H -6.1683546660 5.8809563609 0.1346972792 ForceField.Charge=0.417 ForceField.Type=HW O -1.7022890344 -2.1201620044 -1.4608869577 ForceField.Charge=-0.834 ForceField.Type=OW H -1.6154445327 -2.2947964056 -0.5459476979 ForceField.Charge=0.417 ForceField.Type=HW H -0.7657889701 -2.2035460697 -1.6892361012 ForceField.Charge=0.417 ForceField.Type=HW O 8.4411729502 8.0404027433 -6.4272036783 ForceField.Charge=-0.834 ForceField.Type=OW H 9.3806703752 7.9438402488 -6.7542175360 ForceField.Charge=0.417 ForceField.Type=HW H 7.9969647525 7.2332412922 -6.6445329058 ForceField.Charge=0.417 ForceField.Type=HW O 0.3219110477 3.8786338407 -6.6884570523 ForceField.Charge=-0.834 ForceField.Type=OW H 0.3036151712 2.9032056103 -6.4872457182 ForceField.Charge=0.417 ForceField.Type=HW H 0.6233222991 4.2138339269 -5.8649471339 ForceField.Charge=0.417 ForceField.Type=HW O -7.6107276406 8.8910894157 -1.6367700138 ForceField.Charge=-0.834 ForceField.Type=OW H -8.3324677778 9.3009182508 -1.1379775368 ForceField.Charge=0.417 ForceField.Type=HW H -6.8632956081 9.5133053509 -1.5845242468 ForceField.Charge=0.417 ForceField.Type=HW O 8.2350989412 1.6402964299 1.1205640416 ForceField.Charge=-0.834 ForceField.Type=OW H 8.7033340898 2.5131697780 1.0696061137 ForceField.Charge=0.417 ForceField.Type=HW H 8.8491337363 1.1732414904 1.7649533882 ForceField.Charge=0.417 ForceField.Type=HW O 7.6352676797 0.9303102818 -5.0287548223 ForceField.Charge=-0.834 ForceField.Type=OW H 8.4701742388 1.5566072029 -5.0093470358 ForceField.Charge=0.417 ForceField.Type=HW H 8.0380878419 0.1076786799 -5.3697335822 ForceField.Charge=0.417 ForceField.Type=HW O 3.9355052118 -1.3462543389 -5.6483989644 ForceField.Charge=-0.834 ForceField.Type=OW H 3.5127498884 -1.8067597137 -4.9252150407 ForceField.Charge=0.417 ForceField.Type=HW H 4.5101508669 -0.6748874487 -5.2869375642 ForceField.Charge=0.417 ForceField.Type=HW O 4.1641000216 -7.9472513705 4.7381696337 ForceField.Charge=-0.834 ForceField.Type=OW H 3.8192580505 -7.0754313639 4.7060711322 ForceField.Charge=0.417 ForceField.Type=HW H 4.4045821917 -8.2137060876 3.8845666819 ForceField.Charge=0.417 ForceField.Type=HW O -7.5258850386 -1.5021372447 3.1351269313 ForceField.Charge=-0.834 ForceField.Type=OW H -7.6971523379 -2.1743153577 3.7891316007 ForceField.Charge=0.417 ForceField.Type=HW H -7.7730341658 -1.9478641253 2.3118158664 ForceField.Charge=0.417 ForceField.Type=HW O -5.4323870948 0.7259351255 9.1551740685 ForceField.Charge=-0.834 ForceField.Type=OW H -5.6648295193 0.5262376334 8.2656199764 ForceField.Charge=0.417 ForceField.Type=HW H -5.0926425808 -0.1527307908 9.4086833991 ForceField.Charge=0.417 ForceField.Type=HW O -2.1163904200 6.1997837646 3.4836223016 ForceField.Charge=-0.834 ForceField.Type=OW H -2.1338005341 7.1077236736 3.2504345085 ForceField.Charge=0.417 ForceField.Type=HW H -2.1129163032 5.7896143441 2.6007619521 ForceField.Charge=0.417 ForceField.Type=HW O 9.3954380913 7.6164157923 8.0747355920 ForceField.Charge=-0.834 ForceField.Type=OW H 10.3564240193 7.8027636102 7.9999565365 ForceField.Charge=0.417 ForceField.Type=HW H 8.9584281454 8.2616089057 7.4651695492 ForceField.Charge=0.417 ForceField.Type=HW O -3.9485822012 -8.5045114997 7.2326401785 ForceField.Charge=-0.834 ForceField.Type=OW H -4.4920193156 -7.7197039049 7.3984190305 ForceField.Charge=0.417 ForceField.Type=HW H -3.7009209535 -8.7596709595 8.1617018365 ForceField.Charge=0.417 ForceField.Type=HW O 5.5354965880 1.2172012649 4.1387438788 ForceField.Charge=-0.834 ForceField.Type=OW H 5.6383400824 2.1188429395 4.4502437590 ForceField.Charge=0.417 ForceField.Type=HW H 4.5886319143 1.0198114990 4.3342224385 ForceField.Charge=0.417 ForceField.Type=HW O 4.9551227850 -1.3480466439 7.2170667196 ForceField.Charge=-0.834 ForceField.Type=OW H 4.1447079591 -1.4127271885 6.7145515763 ForceField.Charge=0.417 ForceField.Type=HW H 5.2200043183 -2.3007967549 7.2266164239 ForceField.Charge=0.417 ForceField.Type=HW O 1.1782457657 -0.0790161940 1.0407486236 ForceField.Charge=-0.834 ForceField.Type=OW H 1.5689638146 -0.3787350674 1.9078145342 ForceField.Charge=0.417 ForceField.Type=HW H 0.2669186838 -0.4270332749 1.1317690325 ForceField.Charge=0.417 ForceField.Type=HW O 9.0319205153 6.4710303913 1.2929419181 ForceField.Charge=-0.834 ForceField.Type=OW H 8.0884439301 6.6792429737 1.2958839052 ForceField.Charge=0.417 ForceField.Type=HW H 9.4394980449 7.1957517849 1.7906119224 ForceField.Charge=0.417 ForceField.Type=HW O -4.0461860346 -2.1239164389 6.7486572711 ForceField.Charge=-0.834 ForceField.Type=OW H -3.3768103536 -2.2070034257 7.4754154780 ForceField.Charge=0.417 ForceField.Type=HW H -4.3491232054 -1.1788664551 6.7941508888 ForceField.Charge=0.417 ForceField.Type=HW O -7.2460636765 -3.8290767004 -4.8338380965 ForceField.Charge=-0.834 ForceField.Type=OW H -7.1595336295 -3.5106648607 -5.7405394291 ForceField.Charge=0.417 ForceField.Type=HW H -8.1060532201 -4.1112956672 -4.8448214915 ForceField.Charge=0.417 ForceField.Type=HW O -0.5470497905 -2.4154506995 -5.0564603051 ForceField.Charge=-0.834 ForceField.Type=OW H -1.3419559870 -2.4366707261 -4.5322335953 ForceField.Charge=0.417 ForceField.Type=HW H -0.3656945323 -3.3254275342 -5.2925868581 ForceField.Charge=0.417 ForceField.Type=HW O -4.3135006829 2.2590953322 -8.0305776688 ForceField.Charge=-0.834 ForceField.Type=OW H -5.1316582834 2.7825938623 -7.8262233938 ForceField.Charge=0.417 ForceField.Type=HW H -4.6907371936 1.5786196019 -8.6774208141 ForceField.Charge=0.417 ForceField.Type=HW O -6.4730411692 0.2433954933 6.0500950551 ForceField.Charge=-0.834 ForceField.Type=OW H -7.3646102930 0.4860828258 5.7164789326 ForceField.Charge=0.417 ForceField.Type=HW H -5.9579666181 0.1540206789 5.1953849700 ForceField.Charge=0.417 ForceField.Type=HW O 8.8311801877 -3.7244553009 9.1153232832 ForceField.Charge=-0.834 ForceField.Type=OW H 9.3872479780 -3.1472097709 8.5864082277 ForceField.Charge=0.417 ForceField.Type=HW H 9.4156610324 -4.5287866799 9.2331947808 ForceField.Charge=0.417 ForceField.Type=HW O 5.7414454373 8.0358554984 3.6074367015 ForceField.Charge=-0.834 ForceField.Type=OW H 6.0116195988 8.1738989715 2.6940660088 ForceField.Charge=0.417 ForceField.Type=HW H 6.3747059867 8.5816356116 4.0710466104 ForceField.Charge=0.417 ForceField.Type=HW O -4.4168318725 6.7910192000 9.1772865151 ForceField.Charge=-0.834 ForceField.Type=OW H -4.0268484301 7.6339437122 9.4427439657 ForceField.Charge=0.417 ForceField.Type=HW H -3.8077481190 6.1518419217 9.5697542355 ForceField.Charge=0.417 ForceField.Type=HW O 1.0810406636 8.1564587151 -3.9446522975 ForceField.Charge=-0.834 ForceField.Type=OW H 0.6401112619 9.0176950891 -4.1431867734 ForceField.Charge=0.417 ForceField.Type=HW H 1.6619136680 8.0534985374 -4.7168758350 ForceField.Charge=0.417 ForceField.Type=HW O 0.7910924731 -3.2419149102 -2.5583217065 ForceField.Charge=-0.834 ForceField.Type=OW H 0.2169875642 -3.9613517718 -2.9012901127 ForceField.Charge=0.417 ForceField.Type=HW H 1.1856857189 -3.5434505494 -1.6887503781 ForceField.Charge=0.417 ForceField.Type=HW O -4.8796517285 8.8600267298 -6.5009322948 ForceField.Charge=-0.834 ForceField.Type=OW H -4.2172667770 9.2329920069 -7.1775116988 ForceField.Charge=0.417 ForceField.Type=HW H -4.3178233908 8.6356567051 -5.7409885840 ForceField.Charge=0.417 ForceField.Type=HW O 2.6155346151 1.3910870823 7.7790315289 ForceField.Charge=-0.834 ForceField.Type=OW H 2.6372669778 0.4118253004 7.7366931064 ForceField.Charge=0.417 ForceField.Type=HW H 1.9303530205 1.6196397337 7.1349472548 ForceField.Charge=0.417 ForceField.Type=HW O -0.3646028380 -4.9296590423 -5.7849612041 ForceField.Charge=-0.834 ForceField.Type=OW H -0.7008126023 -5.3477789282 -4.9375030169 ForceField.Charge=0.417 ForceField.Type=HW H -0.7373318342 -5.5375380596 -6.4199655688 ForceField.Charge=0.417 ForceField.Type=HW O -4.4076993972 -5.5965323517 -6.2341891991 ForceField.Charge=-0.834 ForceField.Type=OW H -4.7614506202 -5.0784641062 -5.4835424012 ForceField.Charge=0.417 ForceField.Type=HW H -3.9328885941 -6.2428174205 -5.7390990586 ForceField.Charge=0.417 ForceField.Type=HW O 1.2672201825 -8.8069009787 -7.3391675350 ForceField.Charge=-0.834 ForceField.Type=OW H 0.7909469068 -9.5222247411 -7.6536001530 ForceField.Charge=0.417 ForceField.Type=HW H 1.9416394790 -8.6568438396 -8.0258498113 ForceField.Charge=0.417 ForceField.Type=HW O 8.1336311016 7.9484225223 -1.9142070675 ForceField.Charge=-0.834 ForceField.Type=OW H 8.3598516436 7.0127665497 -1.8978233781 ForceField.Charge=0.417 ForceField.Type=HW H 8.1164237141 8.1737385841 -0.9610021904 ForceField.Charge=0.417 ForceField.Type=HW O 3.5903464173 -3.9513651994 -3.0001477806 ForceField.Charge=-0.834 ForceField.Type=OW H 2.6878370650 -3.7704376175 -3.2375928157 ForceField.Charge=0.417 ForceField.Type=HW H 3.6061106157 -4.9146789259 -2.8319803253 ForceField.Charge=0.417 ForceField.Type=HW O 8.1828399873 -1.9736054004 -0.1469279421 ForceField.Charge=-0.834 ForceField.Type=OW H 8.4727738426 -2.3017763298 0.7451201733 ForceField.Charge=0.417 ForceField.Type=HW H 8.2318632565 -2.7765486864 -0.6207569162 ForceField.Charge=0.417 ForceField.Type=HW O -4.0500095038 -5.9716858516 4.4900488708 ForceField.Charge=-0.834 ForceField.Type=OW H -4.8811566287 -6.1341339620 4.9892119586 ForceField.Charge=0.417 ForceField.Type=HW H -3.5548690676 -6.8103107491 4.4719989845 ForceField.Charge=0.417 ForceField.Type=HW O -8.9023943969 5.7580920315 -1.3474751632 ForceField.Charge=-0.834 ForceField.Type=OW H -8.9762574809 5.2547973252 -0.4516194168 ForceField.Charge=0.417 ForceField.Type=HW H -8.4109544230 6.5772578772 -1.1059513124 ForceField.Charge=0.417 ForceField.Type=HW O -3.3238863301 4.7808193820 -2.9969078450 ForceField.Charge=-0.834 ForceField.Type=OW H -2.6338331194 5.1817616737 -2.4190201171 ForceField.Charge=0.417 ForceField.Type=HW H -3.0896528605 3.8473764440 -2.9320679161 ForceField.Charge=0.417 ForceField.Type=HW O -4.0298327366 2.7791689580 -4.6450232488 ForceField.Charge=-0.834 ForceField.Type=OW H -4.8547279681 2.3035576473 -4.4496286698 ForceField.Charge=0.417 ForceField.Type=HW H -4.2592811121 3.7359864437 -4.5058696052 ForceField.Charge=0.417 ForceField.Type=HW O -1.6722322576 9.3403048705 6.6027983883 ForceField.Charge=-0.834 ForceField.Type=OW H -2.5156863177 9.7024735308 6.9126928528 ForceField.Charge=0.417 ForceField.Type=HW H -1.0001420021 9.7906233213 7.1600855113 ForceField.Charge=0.417 ForceField.Type=HW O 9.0372533116 3.2645246055 7.4333921770 ForceField.Charge=-0.834 ForceField.Type=OW H 9.7218005653 3.8592410609 7.7366222396 ForceField.Charge=0.417 ForceField.Type=HW H 8.2988108076 3.9142254336 7.3587172939 ForceField.Charge=0.417 ForceField.Type=HW O 2.8779720160 -2.4210599434 -7.6950164210 ForceField.Charge=-0.834 ForceField.Type=OW H 3.2151102288 -2.0743479255 -6.8532557109 ForceField.Charge=0.417 ForceField.Type=HW H 3.1924911563 -1.7478534649 -8.2478194471 ForceField.Charge=0.417 ForceField.Type=HW O 8.7087837582 5.5412351888 -9.3329107040 ForceField.Charge=-0.834 ForceField.Type=OW H 8.1471308926 6.0660801881 -8.7163978038 ForceField.Charge=0.417 ForceField.Type=HW H 8.9537269448 6.2748138717 -9.9634852583 ForceField.Charge=0.417 ForceField.Type=HW O -6.8371412465 3.8246241841 5.2025760671 ForceField.Charge=-0.834 ForceField.Type=OW H -6.9546276217 4.4814948812 4.4401257851 ForceField.Charge=0.417 ForceField.Type=HW H -6.0301956166 3.3434498738 4.9771451521 ForceField.Charge=0.417 ForceField.Type=HW O 4.6914804471 8.0932220967 -7.5045743338 ForceField.Charge=-0.834 ForceField.Type=OW H 5.5267143001 7.7803840310 -7.9473899750 ForceField.Charge=0.417 ForceField.Type=HW H 4.9582521159 9.0409905928 -7.1874554565 ForceField.Charge=0.417 ForceField.Type=HW O -3.3152350791 -1.7489577418 2.7618383638 ForceField.Charge=-0.834 ForceField.Type=OW H -3.9993863365 -2.4702711759 2.7334776184 ForceField.Charge=0.417 ForceField.Type=HW H -3.8552361973 -1.0857063456 3.2054938964 ForceField.Charge=0.417 ForceField.Type=HW O 6.1470451427 -2.9972862145 -3.7982957889 ForceField.Charge=-0.834 ForceField.Type=OW H 5.2318096482 -3.3087320250 -3.5542363208 ForceField.Charge=0.417 ForceField.Type=HW H 6.3649556703 -2.4112478016 -3.0737317183 ForceField.Charge=0.417 ForceField.Type=HW O 9.1030421259 -1.1687971235 -6.4585942094 ForceField.Charge=-0.834 ForceField.Type=OW H 9.9749752962 -1.5575026300 -6.1640798189 ForceField.Charge=0.417 ForceField.Type=HW H 8.9020284091 -1.6994350374 -7.2074389841 ForceField.Charge=0.417 ForceField.Type=HW O 9.1746267640 -2.3851455568 5.4148245937 ForceField.Charge=-0.834 ForceField.Type=OW H 8.3477876689 -2.0931038080 5.0692565851 ForceField.Charge=0.417 ForceField.Type=HW H 9.1160467235 -3.3416115330 5.2143907606 ForceField.Charge=0.417 ForceField.Type=HW O 5.6886062318 -3.7915348101 7.0047334312 ForceField.Charge=-0.834 ForceField.Type=OW H 6.4505995501 -4.3848966754 6.9707396094 ForceField.Charge=0.417 ForceField.Type=HW H 4.9750298953 -4.4805970590 7.1347300326 ForceField.Charge=0.417 ForceField.Type=HW O -8.3137579204 -2.0346147343 7.5798038902 ForceField.Charge=-0.834 ForceField.Type=OW H -8.0267499351 -1.0882603256 7.4449881855 ForceField.Charge=0.417 ForceField.Type=HW H -8.9881468170 -2.1612642249 6.8671035918 ForceField.Charge=0.417 ForceField.Type=HW O -2.7546021098 2.5573445222 -1.5158026418 ForceField.Charge=-0.834 ForceField.Type=OW H -2.7194692650 1.6292972089 -1.8734020042 ForceField.Charge=0.417 ForceField.Type=HW H -1.7451506874 2.6837977092 -1.4898154416 ForceField.Charge=0.417 ForceField.Type=HW O 6.3315169847 -9.2085822904 5.8072723320 ForceField.Charge=-0.834 ForceField.Type=OW H 5.5199900938 -8.7973534036 5.6011646019 ForceField.Charge=0.417 ForceField.Type=HW H 6.9583040556 -8.5644297264 5.5898381345 ForceField.Charge=0.417 ForceField.Type=HW O -1.1155639338 -1.5503159752 1.3428490198 ForceField.Charge=-0.834 ForceField.Type=OW H -1.9361859097 -1.5416921854 1.8462704741 ForceField.Charge=0.417 ForceField.Type=HW H -1.0108624953 -2.5210093662 1.0934188578 ForceField.Charge=0.417 ForceField.Type=HW O 9.0776887963 3.0050048499 -3.2955814032 ForceField.Charge=-0.834 ForceField.Type=OW H 8.5154416097 2.3911656563 -2.7936542326 ForceField.Charge=0.417 ForceField.Type=HW H 9.8528229918 3.0675939053 -2.7761959585 ForceField.Charge=0.417 ForceField.Type=HW O 2.2453757742 8.2781904702 2.3274514421 ForceField.Charge=-0.834 ForceField.Type=OW H 2.8478423804 8.9917530037 2.1923965713 ForceField.Charge=0.417 ForceField.Type=HW H 2.6505590822 7.7390454806 2.9692135463 ForceField.Charge=0.417 ForceField.Type=HW O 5.8127612277 5.6055379977 -0.8477187779 ForceField.Charge=-0.834 ForceField.Type=OW H 6.0031438778 4.7049851601 -1.2223801435 ForceField.Charge=0.417 ForceField.Type=HW H 5.8742800299 5.5415262193 0.1364992999 ForceField.Charge=0.417 ForceField.Type=HW O 0.9797638894 0.6369830855 -1.9252382168 ForceField.Charge=-0.834 ForceField.Type=OW H 1.4043885989 0.2162240418 -1.1857743735 ForceField.Charge=0.417 ForceField.Type=HW H 0.6211503677 1.4391063379 -1.5733030457 ForceField.Charge=0.417 ForceField.Type=HW O -8.9718291092 -5.5461703177 -0.1739564713 ForceField.Charge=-0.834 ForceField.Type=OW H -8.6572974432 -5.9776822024 -1.0023531255 ForceField.Charge=0.417 ForceField.Type=HW H -9.8586186420 -5.1800104618 -0.4025179299 ForceField.Charge=0.417 ForceField.Type=HW O -0.1740480629 -1.8255917857 5.3651284924 ForceField.Charge=-0.834 ForceField.Type=OW H -0.6402226185 -0.9914310033 5.1161827506 ForceField.Charge=0.417 ForceField.Type=HW H -0.5479218913 -2.4645506156 4.7521403703 ForceField.Charge=0.417 ForceField.Type=HW O 5.3544671255 -8.1319385307 9.2249102808 ForceField.Charge=-0.834 ForceField.Type=OW H 6.2268386367 -8.1712905978 8.9237429294 ForceField.Charge=0.417 ForceField.Type=HW H 5.3854796712 -8.3666054766 10.1720265092 ForceField.Charge=0.417 ForceField.Type=HW O 8.9777202717 1.3681691749 9.4086471285 ForceField.Charge=-0.834 ForceField.Type=OW H 9.0986297136 1.8166629269 8.5732017907 ForceField.Charge=0.417 ForceField.Type=HW H 8.0845994825 1.0637298348 9.3605204716 ForceField.Charge=0.417 ForceField.Type=HW O 2.0180662773 5.9309009920 -2.6281609812 ForceField.Charge=-0.834 ForceField.Type=OW H 1.6602279430 6.8095335633 -2.8564499834 ForceField.Charge=0.417 ForceField.Type=HW H 1.2376607273 5.3564114005 -2.8788158891 ForceField.Charge=0.417 ForceField.Type=HW O 3.4177704535 2.3898772921 -1.8293576029 ForceField.Charge=-0.834 ForceField.Type=OW H 3.3273596011 1.4870747564 -1.4873984485 ForceField.Charge=0.417 ForceField.Type=HW H 3.0980392945 2.3574927828 -2.7953153381 ForceField.Charge=0.417 ForceField.Type=HW O -9.3522233476 6.5092719746 4.8113609316 ForceField.Charge=-0.834 ForceField.Type=OW H -9.5511795629 7.4466196796 4.6785980437 ForceField.Charge=0.417 ForceField.Type=HW H -8.3973413325 6.3625056741 4.5707373953 ForceField.Charge=0.417 ForceField.Type=HW O 6.4514946673 -5.1783330143 2.8484219564 ForceField.Charge=-0.834 ForceField.Type=OW H 6.0774225251 -5.4190429369 1.9975624761 ForceField.Charge=0.417 ForceField.Type=HW H 6.8323051148 -5.9839343429 3.1538948343 ForceField.Charge=0.417 ForceField.Type=HW O -4.5781383121 -4.4006183677 -9.3971601710 ForceField.Charge=-0.834 ForceField.Type=OW H -4.8533739883 -4.5004339444 -10.3148096760 ForceField.Charge=0.417 ForceField.Type=HW H -4.9148916740 -5.1201320631 -8.9233151709 ForceField.Charge=0.417 ForceField.Type=HW O 6.2305240028 4.7328774552 -4.2352048500 ForceField.Charge=-0.834 ForceField.Type=OW H 6.8048686397 4.2233890669 -3.5887964903 ForceField.Charge=0.417 ForceField.Type=HW H 5.4111077938 4.2686848009 -4.1387849460 ForceField.Charge=0.417 ForceField.Type=HW O 4.9178165091 -5.9398819998 0.5392012303 ForceField.Charge=-0.834 ForceField.Type=OW H 5.1867059173 -6.1181241485 -0.3572001526 ForceField.Charge=0.417 ForceField.Type=HW H 4.4261864936 -5.0835368460 0.4362215100 ForceField.Charge=0.417 ForceField.Type=HW O -3.4759315293 -8.0069394851 -4.2555794186 ForceField.Charge=-0.834 ForceField.Type=OW H -3.3768256530 -8.9862273792 -4.3883558538 ForceField.Charge=0.417 ForceField.Type=HW H -2.8621283353 -7.8424848746 -3.5091647449 ForceField.Charge=0.417 ForceField.Type=HW O -5.2227840527 0.1649132432 3.5369269403 ForceField.Charge=-0.834 ForceField.Type=OW H -6.0938460061 -0.2503772499 3.2997103137 ForceField.Charge=0.417 ForceField.Type=HW H -5.2281283410 1.0851655106 3.1293128482 ForceField.Charge=0.417 ForceField.Type=HW O 2.8049124907 5.0348446891 -5.2718408508 ForceField.Charge=-0.834 ForceField.Type=OW H 2.4343759380 5.3058868583 -4.4417592719 ForceField.Charge=0.417 ForceField.Type=HW H 2.7885169629 4.0154903353 -5.2430321907 ForceField.Charge=0.417 ForceField.Type=HW O 0.6950415479 1.7896731821 5.7670207707 ForceField.Charge=-0.834 ForceField.Type=OW H 1.2488165582 1.9150152544 4.9988923605 ForceField.Charge=0.417 ForceField.Type=HW H -0.1312772478 1.5070208844 5.4545265497 ForceField.Charge=0.417 ForceField.Type=HW O -0.9315167479 8.9874105525 4.0932712014 ForceField.Charge=-0.834 ForceField.Type=OW H -1.1702270500 9.1754891306 5.0331242722 ForceField.Charge=0.417 ForceField.Type=HW H -0.3792548735 8.1723450245 4.1388567459 ForceField.Charge=0.417 ForceField.Type=HW O -1.3585900787 -7.0026169766 -7.1739334558 ForceField.Charge=-0.834 ForceField.Type=OW H -0.6719064104 -7.5277720821 -7.6002890658 ForceField.Charge=0.417 ForceField.Type=HW H -2.1324258438 -7.1956314003 -7.7334189515 ForceField.Charge=0.417 ForceField.Type=HW O 1.2440822811 -4.4129610859 -0.1466336072 ForceField.Charge=-0.834 ForceField.Type=OW H 0.3730431195 -4.4697921018 0.2609604443 ForceField.Charge=0.417 ForceField.Type=HW H 1.5850527181 -5.2556747009 0.1429672058 ForceField.Charge=0.417 ForceField.Type=HW O -8.8915032039 3.9820397341 0.8244482938 ForceField.Charge=-0.834 ForceField.Type=OW H -7.9302397072 4.1280739917 0.7850720632 ForceField.Charge=0.417 ForceField.Type=HW H -9.3211295587 4.7306687516 1.3369130389 ForceField.Charge=0.417 ForceField.Type=HW O 4.2155752474 -0.4578308268 -9.2394504435 ForceField.Charge=-0.834 ForceField.Type=OW H 5.0833703978 -0.1028371184 -8.9799414878 ForceField.Charge=0.417 ForceField.Type=HW H 4.3223557191 -0.7117912069 -10.2075419998 ForceField.Charge=0.417 ForceField.Type=HW O -0.2501471423 3.1460433807 -0.9046195527 ForceField.Charge=-0.834 ForceField.Type=OW H 0.4155587977 3.0355272753 -0.2186276809 ForceField.Charge=0.417 ForceField.Type=HW H -0.5754414112 4.0190215507 -0.7716550684 ForceField.Charge=0.417 ForceField.Type=HW O 3.5581224809 6.7437940261 4.4701208629 ForceField.Charge=-0.834 ForceField.Type=OW H 4.2696446493 7.3788618169 4.3155133410 ForceField.Charge=0.417 ForceField.Type=HW H 3.9723538508 6.2389309690 5.2176502465 ForceField.Charge=0.417 ForceField.Type=HW O 0.8976700794 7.3126894875 5.0505212216 ForceField.Charge=-0.834 ForceField.Type=OW H 0.4644054671 6.6220155659 5.5338694255 ForceField.Charge=0.417 ForceField.Type=HW H 1.8067851275 7.0518833274 4.8233510205 ForceField.Charge=0.417 ForceField.Type=HW O 1.6046873079 -6.8663959929 -3.4516868271 ForceField.Charge=-0.834 ForceField.Type=OW H 1.7167893453 -7.2692933520 -2.5932907444 ForceField.Charge=0.417 ForceField.Type=HW H 2.3634249684 -7.0759988761 -3.9811576184 ForceField.Charge=0.417 ForceField.Type=HW O 9.1759248550 -8.4606701053 -0.2314268847 ForceField.Charge=-0.834 ForceField.Type=OW H 9.4723150096 -7.7964362091 0.3695621689 ForceField.Charge=0.417 ForceField.Type=HW H 8.3441694248 -8.8660676618 0.1949476977 ForceField.Charge=0.417 ForceField.Type=HW O -7.8869247662 0.3890920622 -8.0084462837 ForceField.Charge=-0.834 ForceField.Type=OW H -7.1823994107 0.6156497352 -8.6286567120 ForceField.Charge=0.417 ForceField.Type=HW H -8.6834696606 0.4195724784 -8.5983693091 ForceField.Charge=0.417 ForceField.Type=HW O 6.7931316477 7.8548293022 -8.9563040590 ForceField.Charge=-0.834 ForceField.Type=OW H 7.3544306913 8.6929518749 -8.9839072147 ForceField.Charge=0.417 ForceField.Type=HW H 6.7728230422 7.6992594687 -9.9362908262 ForceField.Charge=0.417 ForceField.Type=HW O 7.4346672708 -5.7120262297 7.4574792197 ForceField.Charge=-0.834 ForceField.Type=OW H 7.3447450707 -5.4734900067 8.4116904235 ForceField.Charge=0.417 ForceField.Type=HW H 8.1616638721 -6.3070297501 7.4461594166 ForceField.Charge=0.417 ForceField.Type=HW O 7.2437375059 -7.9038436695 3.0462431705 ForceField.Charge=-0.834 ForceField.Type=OW H 7.0030303788 -8.4721321667 2.2779657009 ForceField.Charge=0.417 ForceField.Type=HW H 7.4695753372 -8.6066145824 3.7049896840 ForceField.Charge=0.417 ForceField.Type=HW O 8.2882248706 -2.9065512676 2.3948511018 ForceField.Charge=-0.834 ForceField.Type=OW H 8.1145900544 -2.0484527402 2.8667360755 ForceField.Charge=0.417 ForceField.Type=HW H 7.4908616389 -3.4341578469 2.6773535290 ForceField.Charge=0.417 ForceField.Type=HW O 2.9515771464 -5.3029688910 4.7018396551 ForceField.Charge=-0.834 ForceField.Type=OW H 3.2679096804 -5.2958154055 5.6349026476 ForceField.Charge=0.417 ForceField.Type=HW H 2.0364802308 -5.6144631648 4.9128860688 ForceField.Charge=0.417 ForceField.Type=HW O 2.3541758723 -0.9080205200 3.2637616953 ForceField.Charge=-0.834 ForceField.Type=OW H 3.1737311215 -1.3797928708 3.4440842478 ForceField.Charge=0.417 ForceField.Type=HW H 1.7284429785 -1.4639841292 3.6376900862 ForceField.Charge=0.417 ForceField.Type=HW O -5.8656688518 6.9273955746 -0.9830058158 ForceField.Charge=-0.834 ForceField.Type=OW H -5.6655739072 6.7297792313 -1.9103284054 ForceField.Charge=0.417 ForceField.Type=HW H -6.2780161750 7.8407125439 -1.0852330545 ForceField.Charge=0.417 ForceField.Type=HW O -4.9767402718 2.9120463482 3.0404388601 ForceField.Charge=-0.834 ForceField.Type=OW H -5.2342969972 3.7249037119 2.6039425440 ForceField.Charge=0.417 ForceField.Type=HW H -4.0452066690 2.8645786406 2.8836724668 ForceField.Charge=0.417 ForceField.Type=HW O -8.8895397036 -8.0705081003 -7.0666318296 ForceField.Charge=-0.834 ForceField.Type=OW H -9.7359187231 -7.6397025757 -6.7614867914 ForceField.Charge=0.417 ForceField.Type=HW H -8.2482754079 -7.7738507007 -6.4468479775 ForceField.Charge=0.417 ForceField.Type=HW O -6.6983525240 3.3686755719 -7.7881470790 ForceField.Charge=-0.834 ForceField.Type=OW H -6.6372855885 4.0872273792 -8.4829930276 ForceField.Charge=0.417 ForceField.Type=HW H -7.6433214563 3.1183247450 -7.8616200979 ForceField.Charge=0.417 ForceField.Type=HW O -4.3613847285 -3.8867277383 0.0159308795 ForceField.Charge=-0.834 ForceField.Type=OW H -4.6766318726 -3.1258096446 -0.4841858568 ForceField.Charge=0.417 ForceField.Type=HW H -4.7313732437 -3.7489973102 0.9136158205 ForceField.Charge=0.417 ForceField.Type=HW O -4.7586086492 -3.9327206801 2.8164153362 ForceField.Charge=-0.834 ForceField.Type=OW H -5.6988128436 -4.2730206566 2.9591266215 ForceField.Charge=0.417 ForceField.Type=HW H -4.1191810143 -4.5141791048 3.3051677244 ForceField.Charge=0.417 ForceField.Type=HW O -0.3673503997 5.4427455812 -8.6939564617 ForceField.Charge=-0.834 ForceField.Type=OW H -1.2566799563 5.2377235071 -9.0696642552 ForceField.Charge=0.417 ForceField.Type=HW H -0.2420734525 4.7050957954 -8.0664782273 ForceField.Charge=0.417 ForceField.Type=HW O -7.2605551134 -4.3607428609 3.9646771287 ForceField.Charge=-0.834 ForceField.Type=OW H -7.0153284089 -4.6227496942 4.8619919325 ForceField.Charge=0.417 ForceField.Type=HW H -8.2012986814 -4.7278242478 3.8930698778 ForceField.Charge=0.417 ForceField.Type=HW O 1.8380085490 -7.0099393203 1.4040347500 ForceField.Charge=-0.834 ForceField.Type=OW H 2.6773849544 -7.5099579786 1.6504614198 ForceField.Charge=0.417 ForceField.Type=HW H 1.1712098288 -7.2539285931 2.0197282571 ForceField.Charge=0.417 ForceField.Type=HW O -6.5097177008 -6.6519524330 6.1822762434 ForceField.Charge=-0.834 ForceField.Type=OW H -6.6592125999 -5.8164756225 6.6706793472 ForceField.Charge=0.417 ForceField.Type=HW H -7.2458178518 -7.1406675094 6.4906107493 ForceField.Charge=0.417 ForceField.Type=HW O -1.1223583490 -5.9674637552 -3.3737657079 ForceField.Charge=-0.834 ForceField.Type=OW H -1.7826678140 -6.1929316242 -2.6997819255 ForceField.Charge=0.417 ForceField.Type=HW H -0.3740328204 -6.6443590881 -3.3130634223 ForceField.Charge=0.417 ForceField.Type=HW O 6.2471598530 4.5167385450 1.7779398305 ForceField.Charge=-0.834 ForceField.Type=OW H 7.1168477039 4.4406722588 2.2729491915 ForceField.Charge=0.417 ForceField.Type=HW H 5.8839744967 3.6325562059 1.6894828785 ForceField.Charge=0.417 ForceField.Type=HW O 1.7217383560 -7.8560846370 -1.0424116867 ForceField.Charge=-0.834 ForceField.Type=OW H 0.7810819693 -8.1543180548 -1.0545527244 ForceField.Charge=0.417 ForceField.Type=HW H 1.7606068459 -7.4775943831 -0.1226006395 ForceField.Charge=0.417 ForceField.Type=HW O -2.4732058253 0.1134669436 -2.4451408910 ForceField.Charge=-0.834 ForceField.Type=OW H -3.1431898480 -0.1661700536 -3.0776333995 ForceField.Charge=0.417 ForceField.Type=HW H -2.2460353309 -0.6664766981 -1.8744071936 ForceField.Charge=0.417 ForceField.Type=HW O 5.0808765655 0.5993163490 -4.1414903411 ForceField.Charge=-0.834 ForceField.Type=OW H 5.3010674821 0.1057608585 -3.3086408239 ForceField.Charge=0.417 ForceField.Type=HW H 5.9427702946 0.7088965180 -4.5302179576 ForceField.Charge=0.417 ForceField.Type=HW O -1.2810273368 0.3142972176 3.9965590637 ForceField.Charge=-0.834 ForceField.Type=OW H -1.7117758194 -0.1465596841 3.2675996352 ForceField.Charge=0.417 ForceField.Type=HW H -1.3854842407 1.2213244920 3.8139686280 ForceField.Charge=0.417 ForceField.Type=HW O 8.5772076866 4.2053650493 3.4502621767 ForceField.Charge=-0.834 ForceField.Type=OW H 8.6139447656 3.5599468099 4.1207679275 ForceField.Charge=0.417 ForceField.Type=HW H 9.0064719101 4.9402235749 3.8847345605 ForceField.Charge=0.417 ForceField.Type=HW O -0.1563758017 -7.6008458026 7.6831982193 ForceField.Charge=-0.834 ForceField.Type=OW H -0.5513787835 -6.7218030873 7.8656387055 ForceField.Charge=0.417 ForceField.Type=HW H 0.6264455007 -7.5968074798 8.2571922676 ForceField.Charge=0.417 ForceField.Type=HW O -6.5740473678 -1.5458408189 -0.4830413474 ForceField.Charge=-0.834 ForceField.Type=OW H -7.3907741603 -1.9251932478 -0.1206625008 ForceField.Charge=0.417 ForceField.Type=HW H -6.7785775391 -1.4907843897 -1.4364497830 ForceField.Charge=0.417 ForceField.Type=HW O -1.5274181415 5.9667489696 6.1131359653 ForceField.Charge=-0.834 ForceField.Type=OW H -1.6841273052 6.1760780982 5.1529747522 ForceField.Charge=0.417 ForceField.Type=HW H -1.5995801844 6.8175326383 6.5336065990 ForceField.Charge=0.417 ForceField.Type=HW O 2.6040867196 1.9861743385 3.8702947525 ForceField.Charge=-0.834 ForceField.Type=OW H 2.9932200929 2.4023878433 3.1056073048 ForceField.Charge=0.417 ForceField.Type=HW H 2.2113484110 1.1948230463 3.5016066510 ForceField.Charge=0.417 ForceField.Type=HW O -6.5246637734 -8.5716596778 -4.9414389605 ForceField.Charge=-0.834 ForceField.Type=OW H -5.7602727584 -7.9972678735 -4.7723239522 ForceField.Charge=0.417 ForceField.Type=HW H -6.2153993705 -9.2335440592 -5.6438188531 ForceField.Charge=0.417 ForceField.Type=HW O -6.0291890809 -4.0197533959 7.1933612993 ForceField.Charge=-0.834 ForceField.Type=OW H -5.3896639525 -3.4864946186 6.8087601935 ForceField.Charge=0.417 ForceField.Type=HW H -6.6895684815 -3.3782144837 7.5416405544 ForceField.Charge=0.417 ForceField.Type=HW O 2.9298192272 -5.7282645100 -9.0956294539 ForceField.Charge=-0.834 ForceField.Type=OW H 2.4334393232 -6.4626841367 -9.4943028817 ForceField.Charge=0.417 ForceField.Type=HW H 2.5842193499 -5.7304919398 -8.1902766877 ForceField.Charge=0.417 ForceField.Type=HW O -5.2826300532 6.5064756187 -3.6960707103 ForceField.Charge=-0.834 ForceField.Type=OW H -5.8550865624 5.9645323246 -4.2337700104 ForceField.Charge=0.417 ForceField.Type=HW H -4.6548448278 5.8340879466 -3.3866647771 ForceField.Charge=0.417 ForceField.Type=HW O 3.0183307248 2.1817341619 -4.8244820147 ForceField.Charge=-0.834 ForceField.Type=OW H 3.5265871905 1.4108553404 -4.5667796137 ForceField.Charge=0.417 ForceField.Type=HW H 2.6573179331 1.9613875551 -5.7047954590 ForceField.Charge=0.417 ForceField.Type=HW O 7.6095943020 -4.3277759144 -1.6674475033 ForceField.Charge=-0.834 ForceField.Type=OW H 7.3864046752 -3.9498167333 -2.5885789914 ForceField.Charge=0.417 ForceField.Type=HW H 6.9778876247 -5.0317730042 -1.6499277505 ForceField.Charge=0.417 ForceField.Type=HW O 9.0051532477 -5.0382285729 5.1304765258 ForceField.Charge=-0.834 ForceField.Type=OW H 8.1210152041 -4.9399602703 5.6012401113 ForceField.Charge=0.417 ForceField.Type=HW H 9.4422008042 -5.6903243724 5.5912995774 ForceField.Charge=0.417 ForceField.Type=HW O -1.1454032251 -4.2113511829 0.9888833532 ForceField.Charge=-0.834 ForceField.Type=OW H -2.0458355614 -4.3774304481 0.6567377142 ForceField.Charge=0.417 ForceField.Type=HW H -1.3565121869 -4.4299281076 1.9519672254 ForceField.Charge=0.417 ForceField.Type=HW O -5.6474920973 7.9402243363 3.2197446774 ForceField.Charge=-0.834 ForceField.Type=OW H -5.2426179169 8.0717619633 2.3704901512 ForceField.Charge=0.417 ForceField.Type=HW H -5.4471099105 8.8097461729 3.6421588245 ForceField.Charge=0.417 ForceField.Type=HW O 3.4719036502 -8.2639407258 -4.8249130244 ForceField.Charge=-0.834 ForceField.Type=OW H 3.0195717021 -8.8910391615 -5.4222061521 ForceField.Charge=0.417 ForceField.Type=HW H 4.0445993622 -7.8308759882 -5.4263713465 ForceField.Charge=0.417 ForceField.Type=HW O -7.5480422678 2.8516684168 -1.6892916746 ForceField.Charge=-0.834 ForceField.Type=OW H -6.6745796558 2.8788070254 -1.2485876645 ForceField.Charge=0.417 ForceField.Type=HW H -8.0087499935 3.5823281521 -1.2323180077 ForceField.Charge=0.417 ForceField.Type=HW O 1.1202680317 -0.0309087215 -4.6874221655 ForceField.Charge=-0.834 ForceField.Type=OW H 1.3201156458 0.3049899604 -3.8049921608 ForceField.Charge=0.417 ForceField.Type=HW H 0.6573902455 -0.8551228410 -4.4740499692 ForceField.Charge=0.417 ForceField.Type=HW O -2.3852304913 -3.9721923206 5.1528564011 ForceField.Charge=-0.834 ForceField.Type=OW H -3.0274330149 -3.2219873270 5.2628621573 ForceField.Charge=0.417 ForceField.Type=HW H -2.9829147289 -4.7394721521 5.0817363106 ForceField.Charge=0.417 ForceField.Type=HW O 3.6539451969 0.0385063053 -0.1285134594 ForceField.Charge=-0.834 ForceField.Type=OW H 3.0132564677 -0.1879692667 0.5383012214 ForceField.Charge=0.417 ForceField.Type=HW H 4.3317045944 0.4724584473 0.4182175488 ForceField.Charge=0.417 ForceField.Type=HW O -2.8637240952 -2.7652005262 -3.7028857410 ForceField.Charge=-0.834 ForceField.Type=OW H -2.5196246214 -2.5437957664 -2.8310023968 ForceField.Charge=0.417 ForceField.Type=HW H -3.4747666703 -3.5210470526 -3.5675401749 ForceField.Charge=0.417 ForceField.Type=HW O -3.2275557881 8.2634240613 -4.1775677511 ForceField.Charge=-0.834 ForceField.Type=OW H -3.9539911486 7.6556945624 -3.9103818259 ForceField.Charge=0.417 ForceField.Type=HW H -2.6209160254 8.1590104113 -3.4562030952 ForceField.Charge=0.417 ForceField.Type=HW O -7.0821430789 -6.9448386333 0.8967216077 ForceField.Charge=-0.834 ForceField.Type=OW H -6.9892035933 -6.3782265578 1.6136366878 ForceField.Charge=0.417 ForceField.Type=HW H -7.8360384816 -6.5229072605 0.4275253758 ForceField.Charge=0.417 ForceField.Type=HW O 3.6446763965 -5.7433437134 7.2696611322 ForceField.Charge=-0.834 ForceField.Type=OW H 3.9379459785 -6.6907238206 7.2498694004 ForceField.Charge=0.417 ForceField.Type=HW H 3.5545035162 -5.5766801578 8.2458991162 ForceField.Charge=0.417 ForceField.Type=HW O -3.2567795857 6.2969937967 0.5969821342 ForceField.Charge=-0.834 ForceField.Type=OW H -3.4994044890 7.2580064940 0.7395608613 ForceField.Charge=0.417 ForceField.Type=HW H -3.9364114021 6.0648254758 -0.0296892849 ForceField.Charge=0.417 ForceField.Type=HW O -6.5584636065 1.8046503075 -4.0345149834 ForceField.Charge=-0.834 ForceField.Type=OW H -6.4493881382 0.8390826436 -3.7600430145 ForceField.Charge=0.417 ForceField.Type=HW H -6.8794266317 2.2859659742 -3.2715901651 ForceField.Charge=0.417 ForceField.Type=HW O -8.3770001772 -5.8535941534 9.5623361000 ForceField.Charge=-0.834 ForceField.Type=OW H -7.6666050313 -6.2832291709 10.0893812909 ForceField.Charge=0.417 ForceField.Type=HW H -8.4460337323 -6.4785672792 8.8711155111 ForceField.Charge=0.417 ForceField.Type=HW O -5.7786617508 -8.2314368774 -1.1026593500 ForceField.Charge=-0.834 ForceField.Type=OW H -6.2557677518 -7.8198494159 -0.3687463252 ForceField.Charge=0.417 ForceField.Type=HW H -5.2854975809 -7.4633605092 -1.5592085631 ForceField.Charge=0.417 ForceField.Type=HW O -7.8552139125 7.4658381648 -7.2120956186 ForceField.Charge=-0.834 ForceField.Type=OW H -7.7651033677 6.8229501262 -7.9190888260 ForceField.Charge=0.417 ForceField.Type=HW H -7.2404760983 8.1509830654 -7.3908742824 ForceField.Charge=0.417 ForceField.Type=HW O 5.6024403957 -8.5118796097 -6.9822021142 ForceField.Charge=-0.834 ForceField.Type=OW H 5.3490471278 -7.5507846393 -6.9135600192 ForceField.Charge=0.417 ForceField.Type=HW H 6.5452380654 -8.6044629193 -6.6580945751 ForceField.Charge=0.417 ForceField.Type=HW O 6.4300402987 3.3239855756 5.4350492134 ForceField.Charge=-0.834 ForceField.Type=OW H 6.9748015572 4.0623989801 5.6704210761 ForceField.Charge=0.417 ForceField.Type=HW H 6.6657453755 2.7499928652 6.0783508429 ForceField.Charge=0.417 ForceField.Type=HW O -5.8113150923 -6.8505567119 -8.6290129138 ForceField.Charge=-0.834 ForceField.Type=OW H -5.7372450806 -6.6501180019 -7.6434740965 ForceField.Charge=0.417 ForceField.Type=HW H -5.1064343480 -7.5356830053 -8.7230495847 ForceField.Charge=0.417 ForceField.Type=HW O 2.4771499677 -8.2442414291 8.7784799594 ForceField.Charge=-0.834 ForceField.Type=OW H 3.4176975943 -8.5092418014 8.8223466491 ForceField.Charge=0.417 ForceField.Type=HW H 2.1041620408 -8.9517576379 8.2143038204 ForceField.Charge=0.417 ForceField.Type=HW O -5.4615792544 -3.6523412099 -2.9244027042 ForceField.Charge=-0.834 ForceField.Type=OW H -6.1083583642 -3.7213261002 -3.5698896982 ForceField.Charge=0.417 ForceField.Type=HW H -5.6151202816 -4.4413455300 -2.3240314936 ForceField.Charge=0.417 ForceField.Type=HW O 6.4035144731 7.7032909493 7.4779286335 ForceField.Charge=-0.834 ForceField.Type=OW H 6.5525871342 8.3665417793 6.7586349681 ForceField.Charge=0.417 ForceField.Type=HW H 5.4430460161 7.5422237615 7.2680994959 ForceField.Charge=0.417 ForceField.Type=HW O 5.9042145255 -4.5854765683 -9.0219814413 ForceField.Charge=-0.834 ForceField.Type=OW H 6.0406369385 -4.7490000205 -8.0578076007 ForceField.Charge=0.417 ForceField.Type=HW H 5.0146602686 -4.9641763680 -9.2833695669 ForceField.Charge=0.417 ForceField.Type=HW O 2.8064997291 1.1098107944 -7.3858786538 ForceField.Charge=-0.834 ForceField.Type=OW H 3.4638215641 0.7618767083 -8.0233423667 ForceField.Charge=0.417 ForceField.Type=HW H 2.4604604238 0.3142515506 -6.9507268423 ForceField.Charge=0.417 ForceField.Type=HW O -3.8133908741 -0.7977824278 -5.2105083340 ForceField.Charge=-0.834 ForceField.Type=OW H -3.3739722188 -1.5319155643 -4.7655600104 ForceField.Charge=0.417 ForceField.Type=HW H -4.7552586591 -0.9438765954 -4.9257760152 ForceField.Charge=0.417 ForceField.Type=HW O 1.9511029071 2.8479479299 -9.1840796232 ForceField.Charge=-0.834 ForceField.Type=OW H 2.1025066750 2.2726904127 -9.9713330014 ForceField.Charge=0.417 ForceField.Type=HW H 2.1055690509 2.2518372630 -8.4092578924 ForceField.Charge=0.417 ForceField.Type=HW O -5.0392676172 -8.8270928489 4.5303587148 ForceField.Charge=-0.834 ForceField.Type=OW H -4.3486539726 -9.0603717152 5.1926178268 ForceField.Charge=0.417 ForceField.Type=HW H -5.6308240513 -8.2419829428 5.0269419172 ForceField.Charge=0.417 ForceField.Type=HW O -6.8134431533 5.1644026822 -5.5528842069 ForceField.Charge=-0.834 ForceField.Type=OW H -7.0624321861 5.9776623691 -6.0143506329 ForceField.Charge=0.417 ForceField.Type=HW H -6.6188288748 4.6046210691 -6.2936610707 ForceField.Charge=0.417 ForceField.Type=HW O 0.3657762913 7.1218375652 0.8240219735 ForceField.Charge=-0.834 ForceField.Type=OW H 0.1301271080 7.7297586518 0.0944072846 ForceField.Charge=0.417 ForceField.Type=HW H 1.0671014049 7.5670335450 1.2384560180 ForceField.Charge=0.417 ForceField.Type=HW O 7.6309668343 5.2978229481 6.5173662614 ForceField.Charge=-0.834 ForceField.Type=OW H 8.1858018855 5.9435006598 6.0331143807 ForceField.Charge=0.417 ForceField.Type=HW H 7.1099681682 5.8736421691 7.0679590276 ForceField.Charge=0.417 ForceField.Type=HW O 2.2329247437 -1.3244567141 6.7456302199 ForceField.Charge=-0.834 ForceField.Type=OW H 1.4493283729 -1.3477324538 6.1807073999 ForceField.Charge=0.417 ForceField.Type=HW H 2.1183186818 -1.9642349072 7.4834405686 ForceField.Charge=0.417 ForceField.Type=HW O 6.6057604432 0.4506700010 -8.1959299177 ForceField.Charge=-0.834 ForceField.Type=OW H 6.8863994575 -0.3265409703 -8.7363325629 ForceField.Charge=0.417 ForceField.Type=HW H 7.3103695953 0.5295121600 -7.5496952996 ForceField.Charge=0.417 ForceField.Type=HW O 8.2454415629 -8.6391010013 -9.2196821744 ForceField.Charge=-0.834 ForceField.Type=OW H 8.8390056453 -8.4516057067 -8.5536540184 ForceField.Charge=0.417 ForceField.Type=HW H 8.7549274003 -8.6903740480 -10.0193115171 ForceField.Charge=0.417 ForceField.Type=HW O -2.3028580258 -3.1678353059 8.9290156500 ForceField.Charge=-0.834 ForceField.Type=OW H -2.8951061437 -3.7487323749 9.4258830696 ForceField.Charge=0.417 ForceField.Type=HW H -1.6268515016 -3.7971795231 8.6304897195 ForceField.Charge=0.417 ForceField.Type=HW O 9.0861243056 -4.6445128022 -4.9176548494 ForceField.Charge=-0.834 ForceField.Type=OW H 8.7421662701 -5.2187629371 -4.2491846976 ForceField.Charge=0.417 ForceField.Type=HW H 8.3345515917 -4.5129869061 -5.5631244473 ForceField.Charge=0.417 ForceField.Type=HW O -0.6424586997 -8.7664421199 -5.2180888757 ForceField.Charge=-0.834 ForceField.Type=OW H 0.1474908469 -8.6722357305 -5.7410899879 ForceField.Charge=0.417 ForceField.Type=HW H -1.2344866151 -8.1036862259 -5.5366242630 ForceField.Charge=0.417 ForceField.Type=HW O 4.3486575063 -3.1192286563 3.5779864046 ForceField.Charge=-0.834 ForceField.Type=OW H 4.9825425192 -3.7388347748 3.1729540588 ForceField.Charge=0.417 ForceField.Type=HW H 3.7442970009 -3.7448620488 4.0443813522 ForceField.Charge=0.417 ForceField.Type=HW O 5.6806723556 7.4492712661 -4.0125581882 ForceField.Charge=-0.834 ForceField.Type=OW H 5.7402240886 6.5111235971 -4.2276762963 ForceField.Charge=0.417 ForceField.Type=HW H 4.9043021578 7.7613683563 -4.5492474143 ForceField.Charge=0.417 ForceField.Type=HW O -0.5377870693 1.1766461266 -6.2078387484 ForceField.Charge=-0.834 ForceField.Type=OW H 0.1528194454 0.7236774382 -5.6364484212 ForceField.Charge=0.417 ForceField.Type=HW H -0.5164947056 0.5992925473 -6.9979868639 ForceField.Charge=0.417 ForceField.Type=HW O -2.2437539238 -0.1336886031 -7.8581254679 ForceField.Charge=-0.834 ForceField.Type=OW H -2.2600319084 0.0289163070 -8.8076103915 ForceField.Charge=0.417 ForceField.Type=HW H -1.5652017940 -0.8136197359 -7.7893186349 ForceField.Charge=0.417 ForceField.Type=HW O 0.4913475171 -6.6021832165 5.2341143734 ForceField.Charge=-0.834 ForceField.Type=OW H 0.4162439309 -7.4113132169 5.7780689592 ForceField.Charge=0.417 ForceField.Type=HW H 0.0633496036 -6.9268843105 4.4271973191 ForceField.Charge=0.417 ForceField.Type=HW O -0.8361815748 -5.0018283537 7.0867627300 ForceField.Charge=-0.834 ForceField.Type=OW H -0.2591151704 -5.4512173443 6.4414953332 ForceField.Charge=0.417 ForceField.Type=HW H -1.3797620723 -4.4877309241 6.4943048849 ForceField.Charge=0.417 ForceField.Type=HW O -8.6093739375 -1.8673706153 -2.5720062737 ForceField.Charge=-0.834 ForceField.Type=OW H -9.3996699317 -1.3277215158 -2.2963544442 ForceField.Charge=0.417 ForceField.Type=HW H -8.9425140031 -2.5284335273 -3.2153827594 ForceField.Charge=0.417 ForceField.Type=HW O -7.6693323863 4.7361142708 7.5687610932 ForceField.Charge=-0.834 ForceField.Type=OW H -7.1548657928 4.2792178229 6.8204873441 ForceField.Charge=0.417 ForceField.Type=HW H -7.7391938865 5.6545425789 7.2208985772 ForceField.Charge=0.417 ForceField.Type=HW O -7.4309493518 -2.4221489102 -7.3950143185 ForceField.Charge=-0.834 ForceField.Type=OW H -6.7081129524 -2.6247431806 -7.9809609400 ForceField.Charge=0.417 ForceField.Type=HW H -7.7233979332 -1.5639309756 -7.7125538477 ForceField.Charge=0.417 ForceField.Type=HW O 5.4781927536 1.2193417581 1.3539587695 ForceField.Charge=-0.834 ForceField.Type=OW H 5.6634262497 1.3325392666 2.3217928015 ForceField.Charge=0.417 ForceField.Type=HW H 6.3527156678 1.3040077458 0.9683755693 ForceField.Charge=0.417 ForceField.Type=HW O -4.6118380208 -1.5998805974 -9.1119810221 ForceField.Charge=-0.834 ForceField.Type=OW H -4.6542916479 -2.5597076512 -9.3372800794 ForceField.Charge=0.417 ForceField.Type=HW H -3.8963808576 -1.5493749043 -8.4409114341 ForceField.Charge=0.417 ForceField.Type=HW O -9.3477416805 0.6393183889 3.1929268819 ForceField.Charge=-0.834 ForceField.Type=OW H -9.2253794839 0.8045306503 4.1350758538 ForceField.Charge=0.417 ForceField.Type=HW H -8.6140305630 0.0461528273 2.9856387493 ForceField.Charge=0.417 ForceField.Type=HW O 3.2861519538 7.5487291799 -5.3801630455 ForceField.Charge=-0.834 ForceField.Type=OW H 2.9541723851 6.6358038779 -5.5224246071 ForceField.Charge=0.417 ForceField.Type=HW H 3.7892925955 7.6987281911 -6.2247634376 ForceField.Charge=0.417 ForceField.Type=HW O 7.3265677192 -1.6310305416 9.4972053905 ForceField.Charge=-0.834 ForceField.Type=OW H 7.7679362567 -2.4726810823 9.2194982024 ForceField.Charge=0.417 ForceField.Type=HW H 6.4121305894 -1.9325814398 9.5463968291 ForceField.Charge=0.417 ForceField.Type=HW O 6.7310424120 -1.2855351081 3.7452242071 ForceField.Charge=-0.834 ForceField.Type=OW H 5.9221039077 -1.7073425863 3.9920540515 ForceField.Charge=0.417 ForceField.Type=HW H 6.6006406812 -0.3190106502 3.9492663118 ForceField.Charge=0.417 ForceField.Type=HW O -1.6385206794 -0.5037212131 8.4554483737 ForceField.Charge=-0.834 ForceField.Type=OW H -1.0003775086 -0.3687841875 7.7941325876 ForceField.Charge=0.417 ForceField.Type=HW H -1.4831648145 -1.3917353477 8.7406500790 ForceField.Charge=0.417 ForceField.Type=HW O 4.9723697410 2.7110013637 8.6784727358 ForceField.Charge=-0.834 ForceField.Type=OW H 5.7252894827 2.2030140674 8.2580513471 ForceField.Charge=0.417 ForceField.Type=HW H 4.1803230122 2.2577534999 8.3445204128 ForceField.Charge=0.417 ForceField.Type=HW O -0.5519520615 -7.8248761639 2.6715459959 ForceField.Charge=-0.834 ForceField.Type=OW H -0.5402824721 -8.7628341403 3.0176358091 ForceField.Charge=0.417 ForceField.Type=HW H -1.1432994914 -7.8905193122 1.8648452743 ForceField.Charge=0.417 ForceField.Type=HW O 6.7188932517 0.9532570331 7.3935967779 ForceField.Charge=-0.834 ForceField.Type=OW H 6.1800853042 0.1526304281 7.3813772667 ForceField.Charge=0.417 ForceField.Type=HW H 7.4697001129 0.7504651863 6.8898872691 ForceField.Charge=0.417 ForceField.Type=HW O -6.0520464481 0.6998160625 0.6660858727 ForceField.Charge=-0.834 ForceField.Type=OW H -6.9540762166 1.0078788573 0.8301364421 ForceField.Charge=0.417 ForceField.Type=HW H -6.1291334908 -0.1542861281 0.1845533604 ForceField.Charge=0.417 ForceField.Type=HW O -6.5328647880 5.6573586479 -8.9656858606 ForceField.Charge=-0.834 ForceField.Type=OW H -5.8242460177 6.1956888749 -9.3550495650 ForceField.Charge=0.417 ForceField.Type=HW H -7.0481727956 5.4609778107 -9.7755208115 ForceField.Charge=0.417 ForceField.Type=HW O -8.0906743854 -9.2459094964 2.6829629188 ForceField.Charge=-0.834 ForceField.Type=OW H -7.7316097340 -8.8480881648 1.8724302387 ForceField.Charge=0.417 ForceField.Type=HW H -7.3027465139 -9.4176700247 3.1210293184 ForceField.Charge=0.417 ForceField.Type=HW O 6.6367753428 -3.5577420693 -6.3285616483 ForceField.Charge=-0.834 ForceField.Type=OW H 6.4052755238 -3.3737010003 -5.3999572436 ForceField.Charge=0.417 ForceField.Type=HW H 6.1818009305 -2.7853051711 -6.7601038118 ForceField.Charge=0.417 ForceField.Type=HW O 2.2154473507 -4.9406245179 -6.5988054682 ForceField.Charge=-0.834 ForceField.Type=OW H 1.3517115696 -4.7776828875 -6.2001738323 ForceField.Charge=0.417 ForceField.Type=HW H 2.4669053690 -4.1267835202 -7.0319828081 ForceField.Charge=0.417 ForceField.Type=HW O 5.6817027887 -0.9468751382 -1.8856143593 ForceField.Charge=-0.834 ForceField.Type=OW H 6.5118892687 -1.0485777731 -1.4614202508 ForceField.Charge=0.417 ForceField.Type=HW H 5.0766720872 -0.6790739569 -1.2121764580 ForceField.Charge=0.417 ForceField.Type=HW O 7.8312781940 1.0418841346 -1.3510834814 ForceField.Charge=-0.834 ForceField.Type=OW H 7.9333986616 1.4472187642 -0.4746791408 ForceField.Charge=0.417 ForceField.Type=HW H 8.3070857848 0.2406550324 -1.2445125031 ForceField.Charge=0.417 ForceField.Type=HW O 0.6978511551 4.5635542857 7.2748796151 ForceField.Charge=-0.834 ForceField.Type=OW H -0.0012896939 5.0806125653 6.8452733974 ForceField.Charge=0.417 ForceField.Type=HW H 0.8806874075 3.8435766640 6.6433080358 ForceField.Charge=0.417 ForceField.Type=HW O 4.1439349065 -3.1238713777 -0.2470653239 ForceField.Charge=-0.834 ForceField.Type=OW H 4.1341420401 -2.2289555264 0.1895346685 ForceField.Charge=0.417 ForceField.Type=HW H 3.8199247797 -3.1215451673 -1.1614026859 ForceField.Charge=0.417 ForceField.Type=HW O 0.1580781029 -1.4515353919 -7.6351734025 ForceField.Charge=-0.834 ForceField.Type=OW H 0.0037928166 -1.8519092858 -6.6939805429 ForceField.Charge=0.417 ForceField.Type=HW H 0.5413347193 -2.2569479910 -8.0500857800 ForceField.Charge=0.417 ForceField.Type=HW O -6.5452184499 7.9566430769 7.7380061301 ForceField.Charge=-0.834 ForceField.Type=OW H -5.6616451787 7.6969098849 8.0986839513 ForceField.Charge=0.417 ForceField.Type=HW H -6.4184294601 8.8887292806 7.5960561401 ForceField.Charge=0.417 ForceField.Type=HW O 3.1870894719 6.9932495143 -0.5057631131 ForceField.Charge=-0.834 ForceField.Type=OW H 3.0403668854 6.3343536374 0.1536191737 ForceField.Charge=0.417 ForceField.Type=HW H 2.6106325161 6.6396489934 -1.2058339678 ForceField.Charge=0.417 ForceField.Type=HW O -8.7087871334 1.5554438286 5.8129051079 ForceField.Charge=-0.834 ForceField.Type=OW H -9.3445490680 2.0246225543 6.4179718242 ForceField.Charge=0.417 ForceField.Type=HW H -7.9893034428 2.1839107810 5.7429512012 ForceField.Charge=0.417 ForceField.Type=HW O 6.2397751894 3.1847073099 -1.9378746864 ForceField.Charge=-0.834 ForceField.Type=OW H 6.5257576256 2.2345727172 -1.9068326071 ForceField.Charge=0.417 ForceField.Type=HW H 5.2909692588 3.0613022871 -1.7799958368 ForceField.Charge=0.417 ForceField.Type=HW O 3.9279068993 -9.2986986049 -2.2097122040 ForceField.Charge=-0.834 ForceField.Type=OW H 3.7964669536 -9.1066134515 -3.1875616060 ForceField.Charge=0.417 ForceField.Type=HW H 3.1284100778 -8.8882577220 -1.7998640624 ForceField.Charge=0.417 ForceField.Type=HW O 4.4775551503 5.7438541675 6.8010000980 ForceField.Charge=-0.834 ForceField.Type=OW H 4.3628125000 4.8583923195 6.6092852173 ForceField.Charge=0.417 ForceField.Type=HW H 4.4899938347 5.7420744813 7.7405223736 ForceField.Charge=0.417 ForceField.Type=HW O -9.2212254431 6.0635111051 -4.0777957094 ForceField.Charge=-0.834 ForceField.Type=OW H -9.0570703617 5.7733573005 -3.1353926795 ForceField.Charge=0.417 ForceField.Type=HW H -8.8430531247 6.9522975691 -4.2116565652 ForceField.Charge=0.417 ForceField.Type=HW O -3.9549093470 8.8715523781 0.6338638945 ForceField.Charge=-0.834 ForceField.Type=OW H -3.1602040353 9.3500619358 0.4368194372 ForceField.Charge=0.417 ForceField.Type=HW H -4.4988685375 8.9717803372 -0.1551531636 ForceField.Charge=0.417 ForceField.Type=HW O -6.2153882223 -0.9099088465 -3.4980888297 ForceField.Charge=-0.834 ForceField.Type=OW H -7.1495412500 -1.0844676530 -3.2952546770 ForceField.Charge=0.417 ForceField.Type=HW H -5.7725571914 -1.7258236224 -3.1248544888 ForceField.Charge=0.417 ForceField.Type=HW O -8.1717616119 -6.5375847566 -2.8938443288 ForceField.Charge=-0.834 ForceField.Type=OW H -7.4615539867 -7.0434621695 -3.3585673977 ForceField.Charge=0.417 ForceField.Type=HW H -8.9824627793 -7.0342693070 -3.1691071863 ForceField.Charge=0.417 ForceField.Type=HW O 5.3593804673 -6.6144004856 -2.1278722345 ForceField.Charge=-0.834 ForceField.Type=OW H 6.0648707944 -6.9589792678 -2.6686376603 ForceField.Charge=0.417 ForceField.Type=HW H 4.9700277817 -7.4658949189 -1.8517713454 ForceField.Charge=0.417 ForceField.Type=HW O 7.5525645203 5.3214546487 -6.5924081412 ForceField.Charge=-0.834 ForceField.Type=OW H 6.8693461390 5.4821342342 -5.8883109150 ForceField.Charge=0.417 ForceField.Type=HW H 7.0495970275 4.6666917851 -7.1614181694 ForceField.Charge=0.417 ForceField.Type=HW O 3.7095020252 4.8366253693 2.4866413424 ForceField.Charge=-0.834 ForceField.Type=OW H 4.7307232159 4.8584081090 2.3836633071 ForceField.Charge=0.417 ForceField.Type=HW H 3.5145442001 5.6828262028 2.9600612448 ForceField.Charge=0.417 ForceField.Type=HW O 3.8936699377 5.7805389620 -8.9424169254 ForceField.Charge=-0.834 ForceField.Type=OW H 3.9897898803 6.6819733702 -8.5526104113 ForceField.Charge=0.417 ForceField.Type=HW H 4.4987946662 5.1401430629 -8.5529161426 ForceField.Charge=0.417 ForceField.Type=HW O 4.6873252502 -6.0447217092 -6.1925989992 ForceField.Charge=-0.834 ForceField.Type=OW H 5.2563789461 -5.7825458907 -5.4785942825 ForceField.Charge=0.417 ForceField.Type=HW H 3.9034827386 -5.5423186684 -6.0490696143 ForceField.Charge=0.417 ForceField.Type=HW O -4.9861699084 3.0929556961 -0.4454083792 ForceField.Charge=-0.834 ForceField.Type=OW H -4.1808855855 2.8000559351 -0.9264209013 ForceField.Charge=0.417 ForceField.Type=HW H -5.0230085855 2.4582172854 0.2355521817 ForceField.Charge=0.417 ForceField.Type=HW O 1.7360187040 -3.4218579243 8.2420725045 ForceField.Charge=-0.834 ForceField.Type=OW H 2.1688813728 -3.6855015533 9.1205973114 ForceField.Charge=0.417 ForceField.Type=HW H 1.1216718162 -4.1593827800 8.0112108063 ForceField.Charge=0.417 ForceField.Type=HW O -1.1173857753 8.3741201172 -2.2410711888 ForceField.Charge=-0.834 ForceField.Type=OW H -1.3676867315 9.2722203899 -1.9794369004 ForceField.Charge=0.417 ForceField.Type=HW H -0.4373509029 8.5005770549 -2.9071909819 ForceField.Charge=0.417 ForceField.Type=HW End BondOrders 11 12 1.0 11 13 1.0 14 15 1.0 14 16 1.0 17 18 1.0 17 19 1.0 20 21 1.0 20 22 1.0 23 24 1.0 23 25 1.0 26 27 1.0 26 28 1.0 29 30 1.0 29 31 1.0 32 33 1.0 32 34 1.0 35 36 1.0 35 37 1.0 38 39 1.0 38 40 1.0 41 42 1.0 41 43 1.0 44 45 1.0 44 46 1.0 47 48 1.0 47 49 1.0 50 51 1.0 50 52 1.0 53 54 1.0 53 55 1.0 56 57 1.0 56 58 1.0 59 60 1.0 59 61 1.0 62 63 1.0 62 64 1.0 65 66 1.0 65 67 1.0 68 69 1.0 68 70 1.0 71 72 1.0 71 73 1.0 74 75 1.0 74 76 1.0 77 78 1.0 77 79 1.0 80 81 1.0 80 82 1.0 83 84 1.0 83 85 1.0 86 87 1.0 86 88 1.0 89 90 1.0 89 91 1.0 92 93 1.0 92 94 1.0 95 96 1.0 95 97 1.0 98 99 1.0 98 100 1.0 101 102 1.0 101 103 1.0 104 105 1.0 104 106 1.0 107 108 1.0 107 109 1.0 110 111 1.0 110 112 1.0 113 114 1.0 113 115 1.0 116 117 1.0 116 118 1.0 119 120 1.0 119 121 1.0 122 123 1.0 122 124 1.0 125 126 1.0 125 127 1.0 128 129 1.0 128 130 1.0 131 132 1.0 131 133 1.0 134 135 1.0 134 136 1.0 137 138 1.0 137 139 1.0 140 141 1.0 140 142 1.0 143 144 1.0 143 145 1.0 146 147 1.0 146 148 1.0 149 150 1.0 149 151 1.0 152 153 1.0 152 154 1.0 155 156 1.0 155 157 1.0 158 159 1.0 158 160 1.0 161 162 1.0 161 163 1.0 164 165 1.0 164 166 1.0 167 168 1.0 167 169 1.0 170 171 1.0 170 172 1.0 173 174 1.0 173 175 1.0 176 177 1.0 176 178 1.0 179 180 1.0 179 181 1.0 182 183 1.0 182 184 1.0 185 186 1.0 185 187 1.0 188 189 1.0 188 190 1.0 191 192 1.0 191 193 1.0 194 195 1.0 194 196 1.0 197 198 1.0 197 199 1.0 200 201 1.0 200 202 1.0 203 204 1.0 203 205 1.0 206 207 1.0 206 208 1.0 209 210 1.0 209 211 1.0 212 213 1.0 212 214 1.0 215 216 1.0 215 217 1.0 218 219 1.0 218 220 1.0 221 222 1.0 221 223 1.0 224 225 1.0 224 226 1.0 227 228 1.0 227 229 1.0 230 231 1.0 230 232 1.0 233 234 1.0 233 235 1.0 236 237 1.0 236 238 1.0 239 240 1.0 239 241 1.0 242 243 1.0 242 244 1.0 245 246 1.0 245 247 1.0 248 249 1.0 248 250 1.0 251 252 1.0 251 253 1.0 254 255 1.0 254 256 1.0 257 258 1.0 257 259 1.0 260 261 1.0 260 262 1.0 263 264 1.0 263 265 1.0 266 267 1.0 266 268 1.0 269 270 1.0 269 271 1.0 272 273 1.0 272 274 1.0 275 276 1.0 275 277 1.0 278 279 1.0 278 280 1.0 281 282 1.0 281 283 1.0 284 285 1.0 284 286 1.0 287 288 1.0 287 289 1.0 290 291 1.0 290 292 1.0 293 294 1.0 293 295 1.0 296 297 1.0 296 298 1.0 299 300 1.0 299 301 1.0 302 303 1.0 302 304 1.0 305 306 1.0 305 307 1.0 308 309 1.0 308 310 1.0 311 312 1.0 311 313 1.0 314 315 1.0 314 316 1.0 317 318 1.0 317 319 1.0 320 321 1.0 320 322 1.0 323 324 1.0 323 325 1.0 326 327 1.0 326 328 1.0 329 330 1.0 329 331 1.0 332 333 1.0 332 334 1.0 335 336 1.0 335 337 1.0 338 339 1.0 338 340 1.0 341 342 1.0 341 343 1.0 344 345 1.0 344 346 1.0 347 348 1.0 347 349 1.0 350 351 1.0 350 352 1.0 353 354 1.0 353 355 1.0 356 357 1.0 356 358 1.0 359 360 1.0 359 361 1.0 362 363 1.0 362 364 1.0 365 366 1.0 365 367 1.0 368 369 1.0 368 370 1.0 371 372 1.0 371 373 1.0 374 375 1.0 374 376 1.0 377 378 1.0 377 379 1.0 380 381 1.0 380 382 1.0 383 384 1.0 383 385 1.0 386 387 1.0 386 388 1.0 389 390 1.0 389 391 1.0 392 393 1.0 392 394 1.0 395 396 1.0 395 397 1.0 398 399 1.0 398 400 1.0 401 402 1.0 401 403 1.0 404 405 1.0 404 406 1.0 407 408 1.0 407 409 1.0 410 411 1.0 410 412 1.0 413 414 1.0 413 415 1.0 416 417 1.0 416 418 1.0 419 420 1.0 419 421 1.0 422 423 1.0 422 424 1.0 425 426 1.0 425 427 1.0 428 429 1.0 428 430 1.0 431 432 1.0 431 433 1.0 434 435 1.0 434 436 1.0 437 438 1.0 437 439 1.0 440 441 1.0 440 442 1.0 443 444 1.0 443 445 1.0 446 447 1.0 446 448 1.0 449 450 1.0 449 451 1.0 452 453 1.0 452 454 1.0 455 456 1.0 455 457 1.0 458 459 1.0 458 460 1.0 461 462 1.0 461 463 1.0 464 465 1.0 464 466 1.0 467 468 1.0 467 469 1.0 470 471 1.0 470 472 1.0 473 474 1.0 473 475 1.0 476 477 1.0 476 478 1.0 479 480 1.0 479 481 1.0 482 483 1.0 482 484 1.0 485 486 1.0 485 487 1.0 488 489 1.0 488 490 1.0 491 492 1.0 491 493 1.0 494 495 1.0 494 496 1.0 497 498 1.0 497 499 1.0 500 501 1.0 500 502 1.0 503 504 1.0 503 505 1.0 506 507 1.0 506 508 1.0 509 510 1.0 509 511 1.0 512 513 1.0 512 514 1.0 515 516 1.0 515 517 1.0 518 519 1.0 518 520 1.0 521 522 1.0 521 523 1.0 524 525 1.0 524 526 1.0 527 528 1.0 527 529 1.0 530 531 1.0 530 532 1.0 533 534 1.0 533 535 1.0 536 537 1.0 536 538 1.0 539 540 1.0 539 541 1.0 542 543 1.0 542 544 1.0 545 546 1.0 545 547 1.0 548 549 1.0 548 550 1.0 551 552 1.0 551 553 1.0 554 555 1.0 554 556 1.0 557 558 1.0 557 559 1.0 560 561 1.0 560 562 1.0 563 564 1.0 563 565 1.0 566 567 1.0 566 568 1.0 569 570 1.0 569 571 1.0 572 573 1.0 572 574 1.0 575 576 1.0 575 577 1.0 578 579 1.0 578 580 1.0 581 582 1.0 581 583 1.0 584 585 1.0 584 586 1.0 587 588 1.0 587 589 1.0 590 591 1.0 590 592 1.0 593 594 1.0 593 595 1.0 596 597 1.0 596 598 1.0 599 600 1.0 599 601 1.0 602 603 1.0 602 604 1.0 605 606 1.0 605 607 1.0 608 609 1.0 608 610 1.0 611 612 1.0 611 613 1.0 614 615 1.0 614 616 1.0 617 618 1.0 617 619 1.0 620 621 1.0 620 622 1.0 623 624 1.0 623 625 1.0 626 627 1.0 626 628 1.0 629 630 1.0 629 631 1.0 632 633 1.0 632 634 1.0 635 636 1.0 635 637 1.0 638 639 1.0 638 640 1.0 641 642 1.0 641 643 1.0 644 645 1.0 644 646 1.0 647 648 1.0 647 649 1.0 650 651 1.0 650 652 1.0 653 654 1.0 653 655 1.0 656 657 1.0 656 658 1.0 659 660 1.0 659 661 1.0 662 663 1.0 662 664 1.0 665 666 1.0 665 667 1.0 668 669 1.0 668 670 1.0 End Lattice 19.0000000000 0.0000000000 0.0000000000 0.0000000000 19.0000000000 0.0000000000 0.0000000000 0.0000000000 19.0000000000 End End